RNA modification sequencing, RIP-based profiling, arrays and GlycoRNA solutions
Arraystar RNA Modification
Research Expert
SOLUTIONS

RNA modification solutions

Most studies reach modification data through the same three steps: decide which mark matters, choose a route by the resolution the conclusion needs, then confirm the interesting targets. These pages set out how that looks for common research questions, for individual marks and for the sample types the work is done on.

01By research question

A modification project usually starts from a question about either position or pattern. Position questions need site-level chemistry; pattern and comparison questions are usually served faster by an enrichment or array route, with site-level work reserved for the targets that matter.

02By modification

The pages below take one mark at a time and set out the processes it has been linked to, which service line reads it, and which readouts are normally run alongside. The last entry covers studies that read more than one mark from the same samples.

m6A

m6A and transcript fate

Splicing, nuclear export, translation and stability — the four levels a resolved m6A site is usually read against.

Mark-levelfour levels
m6Am

m6Am and the cap-proximal position

The same chemistry as m6A, one nucleotide behind the cap — read against transcript lifetime, translation and cap identity.

Mark-levelcap-proximal
m5C

m5C, R-loops and the DNA damage response

Where m5C work meets R-loop and G-quadruplex biology, and what the design has to do to speak to both.

Mark-levelstructure overlap
m7G

m7G, translation and biomolecular condensates

Internal m7G read against translation and against condensate biology.

Mark-leveltranslation
Ψ

Pseudouridine and translation reprogramming

Pseudouridine read against stability, splicing and the translation of the transcript that carries it.

Mark-leveltranslation
A-to-I

A-to-I editing and the proteome

Editing events that change the read, the codon and sometimes the protein, read at defined positions.

Mark-levelediting
O8G

Oxidative RNA damage and the O8G mark

Oxidative damage on RNA read against translation and transcript turnover.

Mark-leveloxidative stress
ac4C & m1A

ac4C and m1A in translation control

Two marks usually read in the same sentence: translation efficiency and transcript stability.

Mark-leveltranslation
2'-O-Me

2'-O-methylation and the ribose

Methylation of the sugar rather than the base, read through ribose chemistry and against structure, guide RNA and recognition.

Mark-levelribose
EMERGING

Emerging modifications: 2'-O-Me, D and m3C

Three sparsely mapped marks, and what a first controlled study on them can claim.

Mark-levelfrontier

03By sample type

What changes between sample types is not the chemistry but the handling: the input that has to be prepared, the quality checks that apply, and which route the material can support.

CELLS AND TISSUE

Cultured cells and tissue

Total RNA from cultured cells or from fresh or frozen tissue is the most common starting point. Pellets and frozen specimens are handled the same way at the RNA stage, so the preparation notes that matter are the ones about degradation and purity. Each service page states its own quality thresholds and the input it needs.

CLINICAL MATERIAL

Blood and body fluids

Whole blood collected in EDTA tubes is accepted; heparin is not compatible with the downstream procedure. Body fluids are treated as a low-abundance source, so the route is chosen with the starting amount in mind. Handling and storage notes are given on each service page rather than generalised here.

LIMITED MATERIAL

Low-input and scarce samples

Sorted populations, small biopsies and rare material change which route is realistic: some methods tolerate less starting RNA than others, and a comparison across many samples usually starts on the higher-throughput line before site-level work on the targets that differ. Which route fits is decided per project.

04How a project runs

  • Define the question. The mark of interest, the sample type and the comparison being made are discussed before a route is fixed.
  • Check the sample. Input type and quality are reviewed against what the chosen workflow needs.
  • Run the workflow. Sample QC, the modification-specific treatment or enrichment, library construction and sequencing.
  • Analyze and report. Site calling or profile quantification, followed by the analysis set and tables described on the service page.
  • Take it further. Where a screen flagged a target, a site-level or LC-MS readout confirms it independently.
StageWhat happensRequest Quote
ScopingMark, sample type and comparison reviewed; route proposed
ScreeningEnrichment or array line across the sample set
ResolutionSingle-base method on the targets that moved

05FAQ

My question is about a specific site — where do I start?

Start on the single-base line. Those methods report the nucleotide and its modification ratio, which is what a site-level conclusion needs, and the ratio is what can be compared between conditions. An enrichment or array readout describes a region, so it cannot supply the position the question is about.

I have a large sample set but no clear target yet.

The enrichment and array lines are built for that situation. They profile many samples or targets at lower resolution and point to where site-level work is worth doing, so the first pass is a screen rather than a final answer. The targets that differ are then taken into a single-base method or an independent readout.

Can a project use more than one line?

Yes, and most do. Screening narrows the field across the sample set, and site-level or LC-MS work confirms what the screen flagged. The later step is planned from the start rather than added at the end, because a screen returns levels and a confirmed conclusion usually needs either a position or an independent measurement.

What if the modification I care about is not listed?

The list of covered marks is on the modification types page, which also states which of them can be resolved to a single base. If yours is not there, ask — it is worth confirming availability rather than assuming, and where a mark has no single-base route the question has to be framed at region level.

Discuss your RNA modification project

Tell us the modification of interest and the sample type — we will come back with a suitable workflow.